Limited Availability ›
This product has limited availability. Some accessories, replacement parts, or services may still be available when it is no longer available.
CDM-A108 8-Channel 5 V Analog Input Module
24-Bit Resolution
Greatly increases sensor capacity
clima estudos de caso água estudos de caso energia estudos de caso gas flux and turbulence estudos de caso infraestrutura estudos de caso terra estudos de caso

Visão Geral

The CDM-A108 is an analog input module that allows you to easily expand your Campbell Scientific data logging system. The CDM-A108 features a 24-bit, analog-to-digital converter and a low-noise, analog front-end to provide you with superior analog measurements. This module also supports period average measurements and includes both current and voltage excitation channels.

The CDM-A108 has eight differential inputs and two excitation channels. It provides both a 12 V and a switched 12 V port for powering your peripherals and two switched 5 V ports for peripheral control.

Leia mais

Benefícios e Características

  • Ability to make simultaneous measurements
  • CANbus 2.0A/2.0B capable; contact Campbell Scientific for details
  • Increases the number of analog channels in a data logger system
  • Supports period average measurements
  • Includes both current and voltage excitation channels

imagens


3D / CAD Files:

Descrição Técnica

The CDM-A108 offers 24-bit sigma-delta Adc with 16 user programmable notch frequencies from 30,000 Hz to 2.5 Hz, including 50 and 60 Hz. Previous generations of data loggers could notch out 50 or 60 Hz.

Especificações

-NOTE- Additional specifications are listed in the CDM-A108 and CDM-A116 brochure.
Power Requirements 9.6 to 32 Vdc voltage
Mounting Standard 1-in. grid (DIN rail mounting available)
Estimated Accuracy
  • ±(0.04% of reading + offset) 0° to 40°C
  • ±(0.06% of reading + offset) -40° to +70°C
  • ±(0.08% of reading + offset) -55° to +85°C
Number of Channels 8 differential or 16 single-ended
Operating Temperature Range
  • -40° to +70°C (standard)
  • -55° to +85°C (extended)
Maximum Multiplexed Sample Rate 3.0 kHz (using fast [100 μs] input setting)
Maximum Burst Sample Rate 30 kHz
Input Range ±5000 mV, ±1000 mV, and ±200 mV
Period Averaging Traditional period averaging on analog input channels
CPI For data logger connection. Baud rate selectable from 50 kbps to 1 Mbps. (Allowable cable length varies depending on baud rate, number of nodes, cable quality, and noise environment, but can be as long as 700 m under proper conditions.)
USB USB 2.0 full speed connection available for attaching to a PC. (Port is used to configure the module and download updates via our Device Configuration Utility.)
Warranty One year against defects in materials and workmanship
Dimensions 20.3 x 12.7 x 5.1 cm (8 x 5 x 2 in.)
Weight 0.8 kg (1.75 lb)

Typical Current Drain

Sleep <1 mA
Active 1 Hz Scan 2 mA (estimated)
Assumes one single-ended measurement with the first notch frequency (fN1) at 30 kHz
Active 20 Hz Scan 20 mA
Assumes one single-ended measurement with the first notch frequency (fN1) at 30 kHz

Voltage/Current Excitation Outputs

Voltage Excitation ±5 V (@ 50 mA)
Current Excitation ±2.5 mA (±5 V compliance voltage)
Number of Voltage/Current Excitation Outputs 2

General Purpose Outputs

Number of SW5V Outputs 2
SW5V Output Resistance 30 Ω
Number of SW12V Outputs 1
Typical Limit of SW12V Outputs 200 mA
Minimum Limit of SW12V Outputs 180 mA
Number of 12V Outputs 1
Typical Limit of 12V Outputs 200 mA
Minimum Limit of 12V Outputs 180 mA

Compatibilidade

Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.

Data Loggers

Product Compatible Note
CR1000 (retired) To use the CDM-A108 with a CR1000 datalogger, an SC-CPI (data-logger-to-CPI interface) must be used between the data logger and the CDM-A108. 
CR1000X
CR300
CR3000 (retired) To use the CDM-A108 with a CR3000 datalogger, an SC-CPI (data-logger-to-CPI interface) must be used between the data logger and the CDM-A108. 
CR310
CR6
CR800 (retired) To use the CDM-A108 with a CR800 datalogger, an SC-CPI (data-logger-to-CPI interface) must be used between the data logger and the CDM-A108. 
CR850 (retired) To use the CDM-A108 with a CR850 datalogger, an SC-CPI (data-logger-to-CPI interface) must be used between the data logger and the CDM-A108. 

Distributed Data Acquisition

Product Compatible Note
Granite 9

Documentos Relacionados

Downloads

Device Configuration Utility v.2.29 (54 MB) 15-11-2023

A software utility used to download operating systems and set up Campbell Scientific hardware. Also will update PakBus Graph and the Network Planner if they have been installed previously by another Campbell Scientific software package.

Supported Operating Systems:

Windows 11 or 10 (Both 32 and 64 bit)

Visualize o Histórico de Revisões

Artigos e Comunicados de Imprensa