RETIRED ›
This product is no longer available and has been replaced by: CR300. Some accessories, replacement parts, or services may still be available.
CR200X Datalogger
Services Available
Repair Yes
Calibration Yes
Free Support Yes

Visão Geral

O CR200X, nosso datalogger de menor tamanho e custo, oferece operação autônoma em ambientes hostis, remotos. Lê entradas de um ou dois sensores e em seguida transmite os dados usando periféricos de comunicação. CRBasic, sua linguagem completa de programação, permite programação simples ou complexa. Múltiplos CR200Xs podem ser configurados como uma rede ou ser usados individualmente.

Leia mais

Benefícios e Características

  • Ideal applications include wind energy, rural water, water level/flow, aquaculture, water quality
  • Campbell Scientific’s smallest, lowest cost data logger
  • Gas Discharge Tube (GDT) protected inputs
  • Optimal for measuring one or two simple sensors
  • Makes SDI-12, single-ended analog, pulse, switch closure, and bridge measurements
  • Battery-backed clock that ensures accurate time is maintained while data logger is disconnected from battery power
  • Program with LoggerNet, PC400, or Short Cut to fit your setup
  • PakBus, Modbus, and SDI-12 protocols supported

imagens

CR200x standard view top
CR200x standard view bottom
CR200x standard view front
CR200x standard view iso
CR200x standard view left
CR200x standard view right

3D / CAD Files:

Descrição Técnica

The CR200X has several input channels for measuring a variety of sensors. Gas discharge tubes provide rugged electrostatic discharge protection for the inputs.

The CR200X does not make differential measurements and is not compatible with SDM devices, multiplexers, or thermocouples (refer to the Compatibility information for compatible sensors, peripherals, and software). Recalibration services are not offered for the CR200X datalogger.

Especificações

-NOTE- Note: Additional specifications are listed in the CR200X-Series Specifications Sheet.
Maximum Scan Rate 1 Hz
Analog Channels
  • The single-ended analog inputs can also be used as control ports.
  • 5 single-ended (no differential) individually configured
Pulse Count Channels 2
Switched Excitation Channels 2 voltage
Digital Ports
  • Certain digital ports can be used to count switch closures.
  • 2 I/O
Communication Ports 1 RS-232
Switched Battery Port 1
Input Voltage Range 0 to 2500 mV
Analog Voltage Accuracy ±(0.25% of reading + (1.2 mV)x(offset)) at -40° to +50°C
Analog Voltage Resolution 0.6 mV
A/D Bits 12
Operating Temperature -40° to +50°C
Power Requirements 7 to 16 Vdc
Typical Current Drain
  • ~0.2 mA (quiescent)
  • ~3 mA (active)
Protocols Supported PakBus (leaf node only), SDI-12
CE Compliance Standards to which Conformity Is Declared IEC61326:2002
Warranty 3 years
Dimensions 14.0 x 7.6 x 4.8 cm (5.5 x 3.0 x 1.9 in.)
Weight 242 g (8.5 oz)

Memory

Final Storage 512 kB of flash memory for approximately 125,000 data points
Operating System 106 kB of flash memory
Intermediate Storage 8 kB of SRAM for communication buffers, calculations, variables, etc.

Compatibilidade

Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.

Medição e Controle

Product Compatible Note
AM16/32B
AM25T

Software

Product Compatible Note
LOGGERNET Version 2.1 or higher
PC200W
PC400 Version 1.0 or higher
PCONNECT (retired) Version 3.0 or higher
PCONNECTCE (retired) Version 2.0 or higher
Short Cut
VISUALWEATHER Version 2 or higher

Additional Compatibility Information

Communications

The CR200X can communicate with a PC via direct connect, NL201 Network Link Interface, NL240 Wi-Fi Network Link, MD485 multidrop modem, and digital cellular modems. Data can be viewed on an iOS device, an Android device, CD295 DataView II Display, or a user-supplied PDA. To use an iOS or Android device, go to the Apple Store or Google Play and download our LoggerLink Mobile Apps free of charge. User-supplied PDAs require either PConnect or PConnectCE software.

Measurement & Control Peripherals

The CR200X is not compatible with SDM devices and multiplexers.

Sensors

The CR200X can measure a variety of sensors including SDI-12 sensors and 4 to 20 mA sensors. It cannot make differential measurements and is not compatible with the freezing-rain/ice, fuel moisture/temperature, geographic position, present weather, soil heat flux, soil matric water potential, and strain sensors listed on our price lists.

Enclosures

Applications with minimal power requirements can use the ENC200 enclosure to house the data logger and the pn 16869 sealed rechargeable battery. The ENC200 cannot house a barometer or a battery that is larger than the pn 16869. However, an ENC10/12 or ENC12/14 enclosure is adequate for most CR200X-based systems.

Power Supplies

The CR200X uses an external power supply and has a built-in regulator. When connected to the on-board charging circuit, the sealed rechargeable battery should be 7 A h or smaller. Using larger batteries with the data logger's built-in charger may result in excessive PC board heating. This is especially a concern when the battery is deeply discharged or failing with a shorted cell. Campbell Scientific also recommends that solar panels be 10 W or less and wall chargers be 1 A or smaller.

Downloads

CR200X Series OS v.04 (1.29 MB) 22-09-2015

Execution of this download installs the Operating System and Compiler on your computer for the following dataloggers:CR200X, CR206X, CR211X, CR216X and CR295X.  It also updates the support files for the CRBasic Editor.  

Note: Newer CR206X dataloggers (serial # ≥ 19122) and newer CR211X dataloggers (serial # ≥ 19143) have 250 mW radios that must use OS 3 or higher for their datalogger operating system.

Visualize o Histórico de Revisões

Perguntas Frequentes Relacionadas

Number of FAQs related to CR200X: 40

Expandir todosRecolher todos

  1. Not directly. If the CS15-L is connected to a CR200(X) datalogger, the data logger can take the ac measurement and control a solid-state relay based on some threshold within the data logger program. The solid-state relay can then control other relays, solenoids, or motor starters. (Use of a solid-state relay is preferred because the data logger can trigger it with a small 5 Vdc mA signal.) For more information, see the “Measurement and Control Peripherals” section of the operator’s manual.

  2. Yes. The simplest method is to use conditional program statements that execute most of the code based on time. For example, the data could be scheduled to log at 6 a.m. and finish at 8 p.m. using CRBasic instructions such as IfTime(). Another option is to use an IfThen/EndIf construction that does a logical test of light-level measurements based on a light sensor. An additional option is to use calculated sunrise and sunset times along with a combination of RealTime() and Case instructions.

    For more information, see the “Decisions, Decisions, Decisions…” article. 

  3. Current data loggers compatible with the BMP5 Direct SDK are the CR200X-series, CR1000, CR3000, CR800, and CR850.

    Retired compatible data loggers include the CR10X-PB, CR23X-PB, and CR510-PB. These data loggers must have the optional PakBus operating system installed, which is available on the Downloads page of our website.

  4. This might happen because the data logger clock is being adjusted by a remote time source. If this occurs close to the same time that the data logger is due to store data, it can result in either a skipped record or an additional record of data.

    If LoggerNet 4 is used to collect data on a schedule, check the setup for that data logger. Look at the settings on the Clock tab in the LoggerNet Setup Screen. If that is enabled, the clock is checked and set at midnight every day and may interfere with data collection at that same time.

    Skipped scans and power outages could also result in records missing from a data table. Check the data logger’s station status or Status table and look for skipped scans, watchdogs, and low 12 V counts.

  5. If small amounts of data are transferred per transmission, it will not be a problem. Larger amounts of data can overrun buffers in the modem, causing lost data. In that situation, lower the baud rate on the data logger to avoid the issue.

  6. No, because it would not work. The SC32B is used to do the following:

    • Convert data logger logic levels (on the CS I/O port) to RS-232 levels 
    • Optically isolate the data logger from the RS-232 peripheral 
  7. The CRBasic Editor Help contains example program code for all instructions in the data logger. Look for the Example link at the top of each instruction topic. The CRBasic Help Tutorial demonstrates how to access this and other online CRBasic Editor Help files.

    Also, many programming examples can be found in the data logger and sensor manuals that are available on the Campbell Scientific website.

  8. The maximum cable length depends on the interface being used.

    • RS-232 connections will reach 15 m (50 ft).
    • RS-485 connections go beyond 610 m (2,000 ft).
    • IP connections can be routed worldwide. 
  9. A data logger can be programmed to initiate data transfer by using the SendVariables() or ModemCallback() instruction in CRBasic. 

    NOTE: These instructions are not supported in the CR200X operating system.

Estudos de Caso

South Dakota: Canal-Based Irrigation System
The semiarid region just north of the Black Hills in western South Dakota has vast......Leia mais
Washington: ALERT Station Retrofit
The National Weather Service (NWS) operates a network of automated flood-warning stations around Mount St.......Leia mais
Virginia: ALERT System
In the late 1970s, the National Weather Service implemented the Integrated Flood Observing and Warning......Leia mais

Artigos e Comunicados de Imprensa