Short Cut Program Generator for Windows (SCWin)
Eases Programming
Simple way to generate data logger programs
clima estudos de caso água estudos de caso energia estudos de caso gas flux and turbulence estudos de caso infraestrutura estudos de caso terra estudos de caso

Visão Geral

Current Version: 4.4

Short Cut Program Generator (SCWin) is a free, menu-driven, PC-compatible software package that simplifies the creation of data logger programs; it creates a data logger program in seven easy steps.

To download Short Cut, refer to the Downloads section or click the Download Now button.

Leia mais

Benefícios e Características

  • Creates a data logger program in seven easy steps.
  • Generates a printable wiring diagram.
  • Supports both standard sensors and generic measurements (e.g., bridge, pulse).
  • Supports the AM25T, AM16/32B, AM16/32A, AM16/32, AM416, and AM32 multiplexers.
  • Supports CDM and GRANITE VOLT Analog Input Modules.
  • Supports GRANITE TEMP Thermocouple Modules.
  • Supports the AVW200 2-Channel Vibrating Wire Analyzer Module.
  • Supports ET106, ET107, and MetData1 Weather Stations.
  • Includes a reference crop evapotranspiration calculation module and other mathematical calculations.
  • Can be downloaded free of charge; see Downloads section or Download Now button on web page.

imagens

Descrição Técnica

Originally intended to support meteorological and hydrological applications, the initial releases of Short Cut (SCWin) supported over 120 sensors. Now, with additional program generation capabilities, Short Cut supports programming for our multiplexers, AVW200-series Vibrating Wire Interfaces, ET107 stations, ET106 stations, MetData1 stations, and most sensors that can be measured by our data loggers.

Short Cut allows the user to select sensors and choose output data. Short Cut then creates a wiring diagram and a program file for transfer to the data logger. It also includes support for algebraic entry of expressions.

Especificações

Current Version 4.4
Operating System Windows 11 and 10 (Both 32- and 64-bit operating systems are supported.)
Requirement .NET 4.0
Purchased Separately Free download
Software Level Entry
Communications Supported N/A (program generator only)
Scheduled Data Collection Supported N/A (program generator only)
Data Display Supported N/A (program generator only)

Compatibilidade

Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.

Data Loggers

Product Compatible Note
21X (retired)
CR10 (retired)
CR1000 (retired)
CR1000X
CR10X (retired)
CR200X (retired)
CR206X (retired)
CR211X (retired)
CR216X (retired)
CR23X (retired)
CR295X (retired)
CR300
CR3000 (retired)
CR310
CR350
CR500 (retired)
CR5000 (retired)
CR510 (retired)
CR6
CR800 (retired)
CR850 (retired)
CR9000 (retired)
CR9000X (retired)

Distributed Data Acquisition

Product Compatible Note
Granite 10
Granite 6
Granite 9

Additional Compatibility Information

Computer Requirements

Computer operating systems—Windows 10 and 11. Short Cut runs on both 32-bit and 64-bit versions of these operating systems.

Product Support

Short Cut supports more than 100 sensors (including generic measurements), multiplexers, AVW200-series vibrating wire interfaces, and the ET107.

Documentos Relacionados

Lâminas do produto


Downloads

Short Cut v.4.4 (29.3 MB) 16-03-2021

Short Cut creates simple programs for our CR200-series, CR300-series, CR510, CR500, CR10(X), 21X, CR23X, CR6, CR800, CR1000(X), CR3000, CR5000, CR9000X and GRANITE dataloggers. Both mixed array and table data operating systems are supported. Short Cut also supports our ET106, ET107 and MetData1 weather stations. The newest version includes the latest sensor files.

Visualize o Histórico de Revisões

SnowVue 10 Patch for Short Cut v4.4 v.1.0 (3.10 MB) 25-10-2022

This patch adds SnowVue 10 support to ShortCut version 4.4.

Perguntas Frequentes Relacionadas

Number of FAQs related to Short Cut: 15

Expandir todosRecolher todos

  1. The SCWin revision history information can be found through the “Software and OS Revision Histories” web page for Short Cut.

  2. No. Short Cut version 3.0 cannot be used to program the data logger to send data via FTP.

  3. No. Campbell Scientific recommends tracking the battery voltage, program signature, and data logger temperature over time for troubleshooting purposes.

  4. No. A CRBasic or Edlog data logger editor (included in PC400 and LoggerNet software) is needed to write program code for the TDR100. Short Cut for Windows (SCWin) is not designed to handle the many variables of the TDR100.

  5. Yes. In the Water | Level & Flow folder, there is the option to select CS475/CS476/CS477 Radar Water Level Sensor. Click to move the selection to the Selected device window, and enter the SDI-12 address.

  6. Short Cut does not allow mV readings. To record the raw mV data before it is converted to NTU, open the Short Cut file in the CRBasic Editor, and alter the program manually.

  7. It is possible that an older version of Short Cut is being used. Download the latest version of Short Cut.

    For programming assistance, consult the NR01-L instruction manual. For additional assistance, contact Campbell Scientific.

  8. Short Cut for Windows (SCWin) ships in all of Campbell Scientific’s support software packages. It is also available as a free download in the Downloads section of the SCWin product page.

    SCWin can be used to create programs by going through a simple five-step process. The generated data logger program can be used “as is,” or it can be opened up in the CRBasic Editor (the programming editor that is included with RTDAQ, LoggerNet, and PC400). SCWin provides a good example of programming, as well as a head start on a new program.

    Note that any changes made to the CRBasic program cannot be imported back into SCWin.

  9. We do not offer an individual manual for SCWin (Short Cut for Windows). Short Cut information is provided in the LoggerNet, RTDAQ, and PC400 manuals. Information can also be obtained from the Help screens within SCWin.

  10. A free program generator for all Campbell Scientific data loggers is Short Cut for Windows (SCWin). Short Cut can be used to create programs in many situations where Campbell Scientific equipment is used. The Campbell Scientific YouTube channel has a two-part series on using Short Cut.

    In situations where program requirements are too complex or specialized for Short Cut, programs can be written in any text editor that can edit and save plain ASCII text. However, creating an error-free program would be very difficult. The CRBasic Editor that comes with PC400 and LoggerNet provides a programming environment with procedure templates, integrated help, programming examples, the ability to test compile the program before sending it, and many other features that can be very helpful when developing a program.


Artigos e Comunicados de Imprensa