The Campbell Scientific Blog Your source for useful how-to information and helpful expert advice

Pesquisar o Blog


Inscrever-se para o Blog

Receber e-mail quando um novo artigo é publicado. Escolha os temas de seu interesse.


Area / Application

Product Category

Activity

Corporate / News

Insira o seu endereço de email:



Sugerir um artigo

Existe um tópico que você gostaria de saber mais à respeito? Nos informe.

Leave this field empty

Displaying 1 - 9 of 9 articles tagged with: Vibrating Wire

A Deeper Look: Our Role in the Hole

Autor: Michael Adams | Ultima atualização: 04/23/2024 | Comentários: 0

a deeper look: our role in the hole

Have you read the South Dakota: Rock Stability in Large Underground Excavation case study? It’s a short and interesting read, so check it out if you haven’t already. In this blog article, we’ll take a deeper look at Campbell Scientific’s role in a large-cavern, hard-rock... Leia mais

A Closer Look: Resolving Dam Data Discrepancies

Autor: Eric Schmidt | Ultima atualização: 03/05/2024 | Comentários: 0

a closer look: resolving dam data discrepancies

Did you read our Southwest: Solving the Mystery of Erroneous Dam Monitoring Data case study? Want to get some more details? In this article, we’re going to take a closer look at that case study. If you haven’t read the case study yet, please do... Leia mais

Why Is the CR6 the Preferred Automated Monitoring Platform for Geotechnical Applications Worldwide?

Autor: Michael Adams | Ultima atualização: 01/08/2024 | Comentários: 0

why is the cr6 the preferred automated monitoring platform for geotechnical applications worldwide?

If you’re not using a CR6 Automated Monitoring Platform for your geotechnical application, you may be missing out on some key benefits that could help ensure the success of your instrumentation and monitoring network. Based on my 30 years of experience with data-acquisition systems, I’ll... Leia mais

How to Get Accurate Vibrating Wire Measurements with Long Cable Lengths

Autor: Nathanael Wright | Ultima atualização: 10/17/2023 | Comentários: 0

how to get accurate vibrating wire measurements with long cable lengths

Typically, when you use long cable lengths for your vibrating wire measurements, you experience a weaker signal with a greater chance of interference. So, how do you overcome this challenge and improve your measurement quality? Keep reading to find out. At Campbell Scientific, our vibrating wire... Leia mais

Get the Most out of VSPECT®

Autor: Jacqalyn Maughan | Ultima atualização: 08/22/2023 | Comentários: 3

get the most out of vspect<sup>®</sup>

Understanding the benefits of VSPECT® will help ensure you are maximizing your benefits when using this technology. In this article, we’ll explore this topic to provide you with a better measurement experience. Why do Campbell Scientific monitoring platforms give me extra vibrating wire data? Have you ever... Leia mais

Use VSPECT® to Verify: Bad Sensors or Bad Data?

Autor: Jacqalyn Maughan | Ultima atualização: 04/06/2023 | Comentários: 0

use vspect<sup>®</sup> to verify: bad sensors or bad data?

Have you ever thought your bad vibrating wire sensor measurements were caused by erratic or erroneous data? You may be surprised to learn that data issues may not be the cause. If you are using a data-acquisition system other than one of the Campbell Scientific... Leia mais

Troubleshooting Vibrating Wire Piezometers

Autor: Nathanael Wright | Ultima atualização: 03/28/2023 | Comentários: 0

troubleshooting vibrating wire piezometers

Campbell Scientific vibrating wire measurement hardware, with our patented VSPECT® technology, offers a distinct advantage over all other vibrating wire measurement systems. Unlike non-Campbell Scientific vibrating wire interfaces that use pulse counting to derive vibrating wire frequency, Campbell Scientific's VSPECT vibrating wire measurement products use spectral... Leia mais

How to Obtain Vibrating Wire Measurements in Environments with High Electromagnetic Noise

Autor: Timothy Jeppsen | Ultima atualização: 10/07/2020 | Comentários: 0

how to obtain vibrating wire measurements in environments with high electromagnetic noise

In 1997, I had my first introduction to using vibrating wire piezometers to measure groundwater fluctuations. A large engineering firm was monitoring water level to ensure that construction of a large pipeline through the San Bernardino Mountains was not intruding on the groundwater. I was... Leia mais

Why Should You Use a Vibrating Wire Data Logger?

Autor: Robin Deissinger | Ultima atualização: 02/14/2018 | Comentários: 0

why should you use a vibrating wire data logger?

In this short interview, Josh Brown, Market Product Manager of the Infrastructure Group, shares some of the benefits of using a vibrating wire data logger, such as the CRVW3 3-Channel Vibrating Wire Datalogger. Josh was interviewed by Robin Deissinger, the blog editor. Interview Q&A What is... Leia mais