The 28370 is a 24 Vdc power-supply kit that includes a 24 Vdc, 3.8 A power supply, along with hardware for mounting and wiring inside standard Campbell Scientific enclosures. The 28370 with the -UL option, as well as part number 27623, are used in UL508A-certified enclosures assembled at Campbell Scientific.
Leia mais
				
							
							The 28370 kit includes a DIN rail bracket, DIN rail connectors, breakers, and the Phoenix Power Supply. This kit does not contain a battery and therefore requires a PS150, CH150, PS200, CH200 or possibly a larger battery if using it with our data loggers.
The raw kit comes unassembled, but its user manual provides assembly information. If the 28370 is purchased with a prewired or UL enclosure, the 28370 will be assembled at no additional cost. If using it with a standard enclosure, Campbell Scientific will assemble it for an additional fee.
| Nominal Input Voltage | 100 to 240 Vac | 
| AC Input Voltage Range | 85 to 264 Vac | 
| DC Input Voltage Range | 90 to 350 Vdc | 
| AC Frequency Range | 45 to 65 Hz | 
| Current Consumption | 
									
										
  | 
							
| Inrush Surge Current | < 15 A (typical) | 
| Power Failure Bypass | 
									
										
  | 
							
| Input Fuse | 3.15 A (slow-blow internal) | 
| Nominal Output Voltage | 24 Vdc ±1% | 
| Setting Range of Output Voltage | 22.5 to 26 Vdc ( > 24 V constant capacity) | 
| Output Current | 3.8 A (-25° to +60°C) | 
| Derating | 60° to 70°C (2.5%/K) | 
| Residual Ripple | < 40 mVPP (20 MHz) | 
| Peak Switching Voltages Idling | < 100 mVPP (20 MHz) | 
| Maximum Power Dissipation (no load) | 2.5 W | 
| Maximum Power Loss of Nominal Load | 12 W | 
| Weight | 988.83 g (2.18 lb) |